Analisis Linearitas Keluaran Radiasi pada X-Ray Mobile dengan Menggunakan Piranha

  • Nur Mukminah R Jurusan Fisika, Fakultas Sains dan Teknologi, UIN Alauddin Makassar
    (ID)
  • Iswadi Iswadi
  • Ihsan Ihsan Ihsan

Abstract

The research was conducted on the linearity of the output radiation in the mobile X-ray by using Piranha. This study aimed to measure the radiation dose exposure, to determine the relationship between the increase in the voltage of the radiation dose exposure and increase the tube current to the radiation dose exposure, as well as to analyze the radiation output and linearity of the output radiation. Data collection was conducted at the Dr. Tadjuddin Chalid Hospital Makassar in radiological installation. In this study the variables that measured the radiation dose and exposure variables that change the tube current and voltage. The data obtained and analyzed to calculate the value of the output radiation and radiation output linearity in the X- ray mobile. The analysis showed that the X-ray mobile with GE brand that are in radiological installation Dr. Tadjuddin Chalid Hospital has good linearity.

Downloads

Download data is not yet available.

References

Anugerah Firmansyah, 2012, Analisis Kebocoran Radiasi Pada Phywe X-Ray Unit Dengan Surveymeter, Skripsi,.

Aulya Rahayu, 2011, Perbandingan Karakteristik Keluaran Antara Pesawat Sinar-x Toshiba Model DRX-1824B dan Toshiba Model DRX-1603B. BATAN, Layanan Compliance Test Pesawat Sinar-x, http://www.batan.go.id/ptkmr/labptkmr/compliance_test.html (04 Mei 2013).

Departemen Kesehatan RI Direktotat Jendral Pelayanan Medik, 2001, Pedoman Pengujian dan Kalibrasi Alat Kesehatan. Jakarta : DEPKES RI.

Donohue, Daniel P., 2000, An Analysis of Radiographic Quality. New York : PRO-ED, Incorporated.

Dwi Oktavina Winata, 2011, Koefisien Backscatter Faktor Sinar-x Diagnostik dalam Rentang RQR (Radiation Qualities In Radiodiagnostik).

Healt Departmen of Western Australia, 2008, Workbook 1 Mobile Radiographic Equipment. 2nd edition(I). Australia: Healt Departmen of Western Australia. http://www.medgadget.com/2011/03/mobilett_mira_mobile_wireless_xray_from_siemens.html (update: 4/5/2013).

Khan, Faiz M., 2003, The Physics of Radiation Therapy. 2nd edition.

Philadelphia, USA: Lippincott Williams & Wilkins.

Ruslan Hani, Ahmadi dan Handoko Riwidikdo., 2009, Fisika Kesehatan. Jogjakarta: Mitra Cendekia Press.

Surat Keputusan Kepala BAPETEN Nomor 01-P/Ka-BAPETEN/ I-03 tentang Pedoman Dosis Pasien Radiodiagnostik, Jakarta , 2003.