Pemanfaatan Kompleks Polielektrolit sebagai Matriks untuk Immobilisasi Urease dan Aplikasinya sebagai Membran Biosensor Pemonitoran Hg(II)

  • Dhony Hermanto Prodi Kimia, FMIPA-Universitas Mataram
    (ID)
  • Mudasir Mudasir
  • Dwi Siswanta
  • Bambang Kuswandi

Abstract

The preparation of polyelectrolyte complex (PEC) as supporting material of urease immobilisation for  Hg(II) biosensor has done. PEC membrane can be prepared by mixing hydrosol alginate and chitosan hydrosol with 1: 1 ratio at pH of 5.28 approximately. The optimum conditions and characteristics of biosensor was determined. The formed alginate–chitosan PEC membrane was confirmed by using FTIR spectroscopy and SEM analysis. The results shoed that PEC of alginate-chitosan was formed and the proposed biosensor is an excellent platform for sensitive detection of Hg (II).

Downloads

Download data is not yet available.

References

Berger, J., Reist, M., Mayer, J. M., Felt, O., Peppas, N. A., & Gurny, R. (2004). Structure and interactions in covalently and ionically crosslinked chitosan hydrogels for biomedical applications. European Journal of Pharmaceutics and Biopharmaceutics, 57(1), 19–34.

Datta, S., Christena, L. R., & Rajaram, Y. R. S. (2013). Enzyme immobilization: an overview on techniques and support materials. Biotech, 3(1), 1–9.

David, A. E., Sun, N., Yang, V. C., & Yang, A. J. (2006). Chemically surface modified gel (CSMG): An excellent enzyme-immobilization matrix for industrial processes.Journal of Biotechnology, 125, 395–407.

Elçin, A. E., & Elçin, Y. M. (2000). Polycation-coated polyanion microspheres of urease for urea hydrolysis. Artificial Cells, Blood Substitutes, and Immobilization Biotechnology, 28(1), 95–111.

Han, J., Zhou, Z., Yin, R., Yang, D., & Nie, J. (2010). Alginate-chitosan/hydroxyapatite polyelectrolyte complex porous scaffolds: Preparation and characterization. International Journal of Biological Macromolecules, 46(2), 199–205.

Hermanto, D., Mudasir, M., Siswanta, D., &Kuswandi, B. (2019a). Synthesis of Alginate-Chitosan Polyelectrolyte Complex (PEC) Membrane and Its Physical-Mechanical Properties. Journal of Scientific and Applied Chemistry, 22(1), 11–16.

Hermanto, D., Kuswandi, B., Siswanta, D., &Mudasir, M.(2019b). Inhibitive Determination of Hg(II) in Aqueous Solution Using Urease Amperometric Biosensor. Indonesian Journal Of Chemistry, 19(3), 786–795.

Lee, J. W., Kim, S. Y., Kim, S. S., Lee, Y. M., Lee, K. H., &Kim, S. J. (1999). Synthesis and characteristics of the interpenetrating polymer network hydrogel composed of chitosan and poly(acrylic acid). Journal of Applied Polymer Science, 73, 113–120.

Kaban, J., Bangun, H., Dawolo, A. K., & Daniel. (2006). Pembuatan membran kompleks polielektrolit. Jurnal Sains Kimia, 10(1), 10–16.

Kayastha, A. M., Srivastava, P. K., Miksa, B., & Slomkowski, S. (2003). Unique activity of ureases immobilized on microspheres.Journal of Bioactive and Compatible Polymers,18(3), 113–124.

Knill, C. J., Kennedy, J. F., Mistry, J., Miraftab, M., Smart, G., Groocock, M. R., & Williams, H. J. (2004). Alginate fibres modified with unhydrolysed and hydrolysed chitosans for wound dressings. Carbohydrate Polymers, 55(1), 65–76.

Kulig, D., Zimoch-Korzycka, A., Jarmoluk, A., & Marycz, K. (2016). Study on alginate-chitosan complex formed with different polymers ratio.Polymers, 8(5), 1–17.

Kuralay, F., Ozy, H., & Yıldız, A. (2007). Inhibitive determination of Hg2+ ion by an amperometric urea biosensor using poly(vinylferrocenium) film, J. Enzmictec., 40, 1156–1159.

Kuswandi, B. (2003). Simple optical fibre biosensor based on immobilised enzyme for monitoring of trace heavy metal ions. Analytical and Bioanalytical Chemistry, 376(7), 1104–1110.

Lee, S., & Lee, W. (2002). Determination of heavy metal ions using conductometric biosensor based on sol-gel-immobilized urease. Bull. Korean Chem. Soc., 23(8), 1169–1172.

Pereira, E. B., Zanin, G. M., & Castro, H. F. (2003). Immobilization and catalytic properties of lipase on chitosan for hydrolysis and esterification reactions. Brazilian Journal of Chemical Engineering, 20(4), 343–355.

Sirisha, V. L., Jain, A., & Jain, A. (2016). Enzyme Immobilization: An Overview on Methods, Support Material, and Applications of Immobilized Enzymes. Advances in Food and Nutrition Research, 79(1), 179–211.

Tsai, H., & Doong, R. (2005). Simultaneous determination of pH , urea , acetylcholine and heavy metals using array-based enzymatic optical biosensor.Biosensors and Bioelectronics, 20, 1796–1804.

Yabuki, S. (2011). Polyelectrolyte complex membranes for immobilizing biomolecules , and their applications to bio-analysis. Analytical Sciences, 27(7), 695–702.

Published
2019-06-19
How to Cite
Hermanto, D., Mudasir, M., Siswanta, D., & Kuswandi, B. (2019). Pemanfaatan Kompleks Polielektrolit sebagai Matriks untuk Immobilisasi Urease dan Aplikasinya sebagai Membran Biosensor Pemonitoran Hg(II). Al-Kimia, 7(1), 1-9. https://doi.org/10.24252/al-kimia.v7i1.6247
Section
Article
Abstract viewed = 789 times