PENGUKURAN ENTRASCE SKIN EXPOSURE DAN LAJU PAPARAN RADIASI HAMBUR PADA PEMERIKSAAN KEPALA DENGAN METODE TEGANGAN TINGGI DI RUMAH SAKIT BHAYANGKARA MAKASSAR

  • Nur Azmi Anugrah Universitas Islam Negeri Alauddin Makassar
    (ID)

Abstract

This study aimed to identify the usage method of high voltage tube (kV) with doses and velocity of exposure radiation received by patients during the head checkup and to know the point or safe distance from the radiation sources to the patient and the employee of radiation in the radiology room in Bhayangkara  Hospital Makassar . Measuring Entrasce Skin Exposure using multimeter X-Ray Barracuda, and measuring the velocity of exposure radiation using surveymeter at a distance of 1 m, 2 m, and 3 m from the object .The eksposi factor used at voltage tube 70 kV, 80 kV, 90 kV, 100 kV, 110 kV, and the current of tube 200 mA, 160 mA, 100 mA, 50 mA, 20 mA, and time ekspos used 0,250 s. From this research obtained that using of high voltage tube 110 kV produce low Entrasce Skin Exposure 0,590 mGy and using standard voltage tube (kV) 70 kV produce high Entrasce Skin Exposure 4,188 mGy . And measuring the velocity of exposure radiation produce 2500 µSv/h at a distance  1 m, 2200 µSv/h at a distance 2 m, and 1700 µSv/h  at a distance 3 m, with high voltage tube at 110 kV. And using voltage tube 70 kV produce low velocity of exposure radiation of 115 µSv/h at a distance 1 m, 72 µSv/h at a distance 2 m, and 7 µSv/h at a distance 3 m. Results showing that the more high voltage tube the more few Entrasce Skin Exposure received to the patients but bigger the velocity of exposure radiation for the employee of radiation and the community and the close distances from sources, higher the rate of exposure radiation, and vice versa . For that reason , point / safe distance for the employee of radiation room and the public should be at a distance 5 m from the radiation sources.

Keywords : radiation, Entrasce Skin Exposure , velocity of exposure radiation, high voltage

Downloads

Download data is not yet available.

References

Carrol, QB., 1985, “Principle of Radiographic Exposure Processing and QualityControl”, Third Edition, USA, Charless C, Thomas Publisher.

Dhahryan, dkk. 2008. Pengaruh Teknik Tegangan Tinggi terhadap Entrasce Skin Exposure dan Laju Paparan Radiasi Hambur pada Pemeriksaan Abdomen. Berkala Fisika [Online], vol 11. No. 3 Hal103-108.

https://ejournal.undip.ac.id/index.php/berkala_fisika/article/view/2931[21Januari 2018].

ICRP Publication 60. 1991. Recomendations of the International Commission on Radiological Protection, Pergamon Press, Oxford.

International Atomic Energy Agency. 2007. “Dosimetry in Diagnostic Radiology: An International Code of Practice”. Technical Reports Series No. 457,

International Atomic Energy Agency, IAEA Safety Glosarry. 2007. “Terminology Used in Nuclear Safety and Radiation Protection”, Vienna.

Pratiwi, U. 2006. Aplikasi Analisis Citra Detail Phantom dengan Metode Konversi Data Digital ke Data Matrik untuk Meningkatkan Kontras Citra Menggunakan Film Imaging Plate. Surakarta: Universitas Sebelas Maret.

Rasad, Sjahriar. 2005. Radiologi Diagnostik Edisi Kedua. Jakarta: Balai Penerbit FK UI, 453- 455.

Van der Plats, 1972. Medical X-Ray Technique. Third Edition, Philips Technical Library, Eindhoven.

Published
2018-06-30
How to Cite
Anugrah, N. A. (2018). PENGUKURAN ENTRASCE SKIN EXPOSURE DAN LAJU PAPARAN RADIASI HAMBUR PADA PEMERIKSAAN KEPALA DENGAN METODE TEGANGAN TINGGI DI RUMAH SAKIT BHAYANGKARA MAKASSAR. JFT: Jurnal Fisika Dan Terapannya, 5(1), 62-71. https://doi.org/10.24252/jft.v5i1.15970
Section
Artikel
Abstract viewed = 318 times