The Purpose of this research is to know the effects of time irradiation to dosage in calibration dosimeter pocket gamma (pen dosimeter).  This research is also intended to know the effects of time irradiation in response dosimeter pocket gamma (pen dosimeter).  Relations between time irradiation to dosage based on calculations time irradiation, irradiation in pen dosimeter to calculate dosage reading material. Result of contact time irradiation with the dose by more than dosage that used time irradiation needed more for a long time. Results obtained from the relationship time irradiation in response dosage is becoming more time irradiation then dosage that read in pen dosimeter result in more than. dosage 100 µSv, 500 µSv, 1000 µSv, 1500 µSv, 2000 µSv, 2500 µSv, 3000 µSv, 3500 µSv, 4000 µSv, and 4,500 µSv, factors calibration 0.91 . Calibration factor which is obtained from pen dosimeter that has been calibration claimed could be used and functioned as specifications based on standard calibration.

Downloads

Download data is not yet available.

References

Alatas, Zubaidah, 2003, Efek Radiasi Pajanan pada Dosis Rendah, http://www.iaea.org/inis/collection/NCLCollectionStore/_Public/42/105/42105369.pdf.

Anies, 2006, SUTET : Potensi Gangguan Kesehatan Akibat Radiasi Elektromagnetik SUTET, Jakarta: Elex Media Komputindo

Anggraini, Dian, dkk., 2010, Ketidakpastian pengukuran Isotop Cs-137 dalam bahan Bakar U_3 〖Si〗_2-Al pasca irradiasi, Online, http://digilib.batan.go.id/ppin/.../0854-5561-2009-580.pdf.

Badan Tenaga Nuklir Nasional (BATAN), 2012, Petugas Proteksi Radiasi: Medik Tingkat 2 dan Tingkat 3, Jakarta: BATAN.

Badan Tenaga Nuklir Nasional (BATAN), Pengenalan Radiasi, Online, http://www.batan.go.id/pusdiklat/elearning/proteksiradiasi/pengenalan_radiasi/judul.htm.

Budiantari, Tuti, 2006, Pelatihan Kalibrasi Alat Ukur Radiasi, Jakarta: BATAN

Cerdas dkk., Taringan, 2000, Perbandingan Kandungan Cs-137 dan Sr-90 Dalam Air Kali Cilasak dan Cipelang, Pusat Pengembangan Pengelolaan Limbah Radioaktif, Sumatera Utara: Universitas Sumatera Utara Fachruddin, Imam, Mengenal Fisika Nuklir. Online, Departemen Fisika Universitas Indonesia. http://staff.fisika.ui.ac.id/imamf/pdf.

Martono, Tahun Terbit, Konsep Cahaya Dalam Al-Qur’an dan sains, Yogyakarta : UIN Sunan Kalijaga.

Rosidah, Fitri, 2009, Efektivitas dekontaminan Ammonium Iron (III) Hexacyanoferrate (〖NH〗_4 Fe[Fe(CN)_6 ]) terhadap Cs-137 pada Monyet Ekor Panjang, Skripsi, Jakarta: Fakultas Sains dan Teknologi UIN Syarif Hidayatullah.

Shihab, M., Quraish, 2009, Tafsir Al-Misbah: pesan, kesan dan keserasian Al-Qur’an, volume 5, Jakarta: Lentera Hati.

Shihab, M. Quraish, 2009, Tafsir Al-Misbah: pesan, kesan dan keserasian Al-Qur’an, volume 9, Jakarta: Lentera Hati.

Shihab, M. Quraish, 2002, Tafsir Al-Misbah: pesan, kesan dan keserasian Al-Qur’an, volume 14, Jakarta: Lentera Hati.

Nama Penulis, Tahun Terbit, Radioaktivitas, Pendidikan Fisika Universitas Pendidikan Indonesia, Online, http://file.upi.edu/Direktori/FPMIPA/JUR._PEND._FISIKA/195708071982112-WIENDARTUN/2._Radioaktivitas.pdf.

Wiyatmo, Yusman, 2012, Fisika Nuklir : Dalam Telaah Semi-Klasik dan Kuantum, Yogjakarta: Pustaka Pelajar.

Published
2015-12-30
How to Cite
Herianti, H., Sahara, S., & Hernawati, H. (2015). ANALISIS WAKTU PENYINARAN PADA KALIBRASI DOSIMETER SAKU GAMMA (PEN DOSIMETER). JFT: Jurnal Fisika Dan Terapannya, 2, 7-13. https://doi.org/10.24252/jft.v2i0.16875
Section
Artikel
Abstract viewed = 566 times

Most read articles by the same author(s)

> >>